I have 2 x 2TB SATA drives I need to install on RAID 6 array. These two drives will need to replace two of the current drives as there are no more free bays. I need someone to direct me through the whole process.
More Information - Smart Array P410i in Embedded Slot
Internal Controller
Controller Status OK
Controller Smart Array P410i
Slot 0
Controller Serial Number 50014380165F2BB0
Bus Interface PCI
Hardware Revision C
Firmware Version 5.14
RAID 6 (ADG) Status Disabled
Rebuild Priority High
Transformation Priority Medium
Surface Scan Analysis Priority Idle
Surface Scan Delay 15 sec
RAID 6/60 Alternate Inconsistency Repair Policy Disabled
RAID 5/6/50/60 Degraded Mode Performance Optimization Disabled
Physical Drive Request Elevator Sort Enabled
Monitor and Performance Analysis Delay 60 min
Maximum Drive Request Queue Depth Automatic
Number of Ports 2 (Internal only)
Number of Arrays 2
Number of Logical Drives 2
Number of Physical Drives 8
Array Accelerator
Array Accelerator Present Yes
Cache Status OK
Array Accelerator (Cache) Ratio 25% Read / 75% Write
Total Cache Size 1024 MB
Cache Backup Power Source Capacitor
Battery/Capacitor Pack Count 1
Battery/Capacitor Status OK
Arrays
SAS Array A - 1 Logical Drive(s)
SAS Array B - 1 Logical Drive(s)
Logical Drive(s) / Local OS Access Name
Logical Drive 1 (1.6 TB, RAID 5) \\.\PhysicalDrive0
Logical Drive 2 (1.6 TB, RAID 5) \\.\PhysicalDrive1
Assigned Drives
600 GB 2-Port SAS Drive at Port 1I : Box 1 : Bay 1
600 GB 2-Port SAS Drive at Port 1I : Box 1 : Bay 2
600 GB 2-Port SAS Drive at Port 1I : Box 1 : Bay 3
600 GB 2-Port SAS Drive at Port 1I : Box 1 : Bay 4
600 GB 2-Port SAS Drive at Port 2I : Box 1 : Bay 5
600 GB 2-Port SAS Drive at Port 2I : Box 1 : Bay 6
600 GB 2-Port SAS Drive at Port 2I : Box 1 : Bay 7
600 GB 2-Port SAS Drive at Port 2I : Box 1 : Bay 8
Unassigned Drives
None
Spare Drives
None
HI,
As per your requirement, I have expertise in Raid Configuration I can help you in that I have done this type of projects much time for my clients.
Let me handle this.
Thanks
waiting for your response
$155 USD në 3 ditë
4,9 (26 përshtypje)
4,8
4,8
6 freelancers are bidding on average $174 USD for this job
Hello,
I’ve just placed a bid so I can let you know that this isn’t likely possible. It looks like your array is made from 600GB disks. If you install the new 2tb disks you will only be able to use 600gb of that 2TB.
All disks in an array should be the same size ideally. You could however start from scratch and put the 1.6 TB and 2TB disks into a RAID Array and build another array with the remaining 600GB disks.
I can't reply to your message until you send something
I think what you want to do is that you want to add one 2TB HDD in Logical Drive 1 and the 2nd 2TB HDD in Logical Drive 2???
For this case you have to give me Remote session or share me the images of the Intelligent Provisioning option in BIOS from where we will go to SSA System Storage Administration and will verify the RAID level.
I am currently working in HPE Enterprise Support in Pakistan.